Control of P-BUS Devices
Editing the P-BUS Timeline
This section describes how to set an action for a keyframe point, and edit the
P-BUS timeline.
Note
Using the P-BUS timeline function requires the P-BUS control mode to be set
to [Timeline]. Carry out this setting in the Engineering Setup>Panel>Device
Interface menu.
Setting an action
To set an action, use the following procedure.
1
2
3
14
Control of P-BUS Devices
In the Device menu, press VF2 'P-Bus Timeline.'
The Device>P-Bus Timeline menu appears.
The status area shows two lists. The left list is for setting combinations of
devices and actions. The settings in this list will be saved as keyframe point
data. The right list is for selecting the action.
Using any of the following methods, select the P-BUS device for which
you want to set an action.
• Press directly on the left list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn knob 1 to make the setting.
Knob
Parameter
1
Device No.
Using either of the following methods, select the action.
• Press directly on the right list in the status area.
• Turn knob 2 to make the setting.
Knob
Parameter
2
Action No.
a) 1: Off (no specification)
2: Store
Adjustment
Device number
Adjustment
Action
Setting values
1 to 24
Setting values
a)
1 to 4