Motorola AP-51 series Product Reference Manual page 432

Hide thumbs Also See for AP-51 series:
Table of Contents

Advertisement

8-84
AP-51xx Access Point Product Reference Guide
secret
<sidx>
reauth
mode
period
retry
accounting
mode
server
port
secret
timeout
retry
syslog
ip
adv
mu-quiet
mu-timeout
mu-tx
<secret>
Sets the EAP shared secret <secret>
characters) for server <sidx> (1-primary or 2-
secondary).
The default password is now "motorola" instead
of "symbol." Be cognizant of this when importing
a configuration from 1.1 to 2.1, as this shared
secret will have to be changed to motorola (after
the import) to avoid MU authentication failures.
This change can only be made using the access
point CLI.
<mode>
Enables or disables EAP reauthentication.
<time>
Sets the reauthentication period <period> in
seconds (30-9999).
<number>
Sets the maximum number of reauthentication
retries <retry> (1-99).
<mode>
Enable or disable Radius accounting.
<ip>
Set external Radius server IP address.
<port>
Set external Radius server port number.
<secret>
Set external Radius server shared secret
password.
<period>
Defines MU timout period in seconds (1-255).
<number>
Sets the maximum number of MU retries to
<retry> (1-10).
<mode>
Enable or disable syslog messages.
<ip>
Defines syslog server IP address.
<time>
Set the EAP MU/supplicant quiet period to
<time> seconds (1-65535).
<timeout>
Sets the EAP MU/supplicant timeout in seconds
(1-255).
<time>
Sets the EAP MU/supplicant TX period <time> in
seconds (1-65535).
(1-63