Test Settings

Once the DVR has been properly configured and the necessary settings entered into the i-viewnow.com portal, it is a
good idea to test each alarm input on the DVR by triggering the corresponding device on your alarm panel.
If relay 1, connected to input 1 on the DVR is supposed to trigger when a panic button is pushed, ensure not only that
the DVR has received the signal, but that the i-viewnow.com portal has received the signal and correctly identifies the
type of alarm.

Picture Clarity

There is an option to change the substream picture quality in either the multi-site 4200 software or the web interface to
the DVR. The substream should be set to CIF with a frame rate of 6. This will provide higher quality frames at a reduced
rate.