Remote Control Tf 26; Connection For Remote Control Tf 26 - Honeywell DHC 23 Operating Instructions Manual

Digital district heating controller
Table of Contents

Advertisement

REMOTE CONTROL TF 26

Connection of TF 26
to DHC 23
26

Connection for remote control TF 26

The most important function of the DHC 23 can be remotely controlled from the living
room with the comfortable remote control TF 26:
– Set setpoint for the room temperature
– Switch heating on or off
auto
Heating and domestic hot water readiness are switched on corresponding
to the set switching times. The room temperature is reduced to the night
setpoint during the night (night shutdown).
The heating is on round the clock. Domestic hot water readiness is switched
on corresponding to the set switching times.
Heating is off. Domestic hot water readiness is switched on corresponding to
the set switching times.
Knob for the room temperature setpoint, effective only in the
position of the TF 26 operating mode switch.
Setting range:
Mid position:
The setting of the remote control TF 26 is added to the setting on the DHC 23. For
instance, if 19°C is set as setpoint on the DHC 23 and +2 K on the remote control, then
an effective setpoint of 21°C results.
–7 . . . +7 K
0 K
DHC 23
and auto