Makita GM series Instruction Manual And Safety Instructions page 22

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
GB
- If the compressor is located on a shelf or on a top above floor height,
it must be secured to prevent it falling while in operation.
- Do not put objects or your hands inside the protective grilles to avoid
injury to yourself or damaging the compressor. (fig. 36)
- Do not use the compressor as a blunt object toward things or animals,
to avoid serious damage.
- When you have finished using the compressor, always remove the
plug from the power socket.
ELECTRO-COMPRESSOR MODELS GM – TR
Maximum operating pressure 8.5 bar
Minimum operating pressure 8 bar
ELECTRO-COMPRESSOR MODELS VX
Maximum operating pressure 10.5 bar
Minimum operating pressure 10 bar
ELECTRO-COMPRESSOR MODELS AB
Maximum operating pressure 10.5 bar
Minimum operating pressure 10 bar
N.B. Two-stage compressors can be supplied on request for use up to
14 bar. In this case:
Maximum operating pressure 14.75 bar
Minimum operating pressure 14 bar
NOTE: The Silent model consists of the AB model completed with a
soundproofing cabinet. The technical data and the instructions of this
manual for the AB models also apply to the derived Silent models.
For the European market, the compressor tanks are manufactured to
meet Directive CE2009/105
For the European market, the compressors are manufactured to meet
Directive CE2006/42.
Acoustic pressure measured free-field at a distance of 1m: ±3dB(A) at
maximum operating pressure. (tab. 3)
GM
HP/kW
RPM
dB(A)
0.65/0.5
1450
73
0.65/0.5
2800
75
0.75/0.65 1700-1450
73
1.5/1.1
3400-2850
75
2/1.5
2850
79
2.5/1.8
2850
82
TR
HP/kW
RPM
dB(A)
1.5/1.1
1700-2800
7 6
2/1.5
2800
80
AB
Mod.
HP/kW
dB(A)
CCS
2 – 1.5
77
AB 245
2 – 1.5
78
AB 335
3 – 2.25
80
AB 410
3 – 2.25
80
AB 510
4 – 3
85
AB 480
4 – 3
81
AB 530
4 – 3
82
AB 550
5.5 – 4.1
83
AB 671
5.5 – 4.1
84
AB 851
7.5 – 5.5
83
AB 1000
10 – 7.5
88
VX
HP/kW
RPM
dB(A)
1.5/1.1
1450
75
2/1.5
1700-1450
75
2.5/1.8
14050
75.5
3/2.2
2850
80
/
/
/
22
The level of acoustic pressure can increase from 1 to 10 dB(A)
The level of acoustic pressure can increase from 1 to 10 dB(A)
according to the place in which the compressor is installed.
according to the place in which the compressor is installed.
The electric compressors on wheels with power greater then or equal
HINTS FOR EFFICIENT OPERATION
to 3 Hp are intended for indoor use.
- For efficient operation of the machine at full continuing load and at
HINTS FOR EFFICIENT OPERATION
maximum operating pressure, make sure the temperature of the work
-For efficient operation of the machine at full continuing load and at
environment indoors does not exceed +25°C.
maximum operating pressure, make sure the temperature of the work
- We advise you to use the compressor at 70% maximum duty per
environment indoors does not exceed +25°C.
hour at full load as this ensures efficient operation of the product
-We advise you to use the compressor at 70% maximum duty per
long-term.
hour at full load as this ensures efficient operation of the product
long-term.
STORING THE PACKED AND UNPACKED COMPRESSOR
For the whole time that the compressor is not used before unpacking it,
STORING THE PACKED AND UNPACKED COMPRESSOR
store it in a dry place at a temperature between +5°C and + 45°C and
For the whole time that the compressor is not used before unpacking
sheltered away from weather.
it, store it in a dry place at a temperature between +5°C and + 45°C
For the whole time that the compressor is not used after unpacking it,
and sheltered away from weather. For the whole time that the
while waiting to start it up or due to production stoppages, place sheets
compressor is not used after unpacking it, while waiting to start it up
over it to protect it from dust, which may settle on the components. The
or due to production stoppages, place sheets over it to protect it from
oil is to be replaced and the operational efficiency of the compressor is
dust, which may settle on the components. The oil is to be replaced
to be checked if it is not used for long periods.
and the operational efficiency of the compressor is to be checked if it
is not used for long periods.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic tubes for compressed air with
PNEUMATIC CONNECTIONS
maximum pressure characteristics that are adequate for the compressor.
Make sure you always use pneumatic tubes for compressed air with
Do not attempt to repair tubes if faulty.
maximum pressure characteristics that are adequate for the
compressor. Do not attempt to repair tubes if faulty.
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS
WE RESERVE THE RIGHT TO MAKE ANY
WITHOUT PRIOR NOTICE WHENEVER NECESSARY.
MODIFICATIONSWITHOUT PRIOR NOTICE WHENEVER
NECESSARY.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vx seriesCcs seriesAb seriesTr series

Table of Contents