Simple Connection Of The Mks-8080/8082 Aux Bus Remote Panel; Procedure For Simple Connection; Setting Status Of The Mks-8080/8082 In Simple Connection - Sony MVS-3000 System User Manual

Multi format switcher system
Hide thumbs Also See for MVS-3000 System:
Table of Contents

Advertisement

Button
KEY SS
a) When the [MSTR] button is On.
b) When the [MSTR] button is Off
c) When the [SNAPSHOT] button is On.
Simple Connection of the
MKS-8080/8082 AUX Bus
Remote Panel

Procedure for Simple Connection

To connect the MKS-8080/8082 AUX Bus Remote Panel
to the control panel using an S-Bus data link requires a
HKSP-R80 Routing Switcher Controller Board or similar
primary station and various settings for connection.
However, using a simple connection, the need for an S-Bus
data link primary station is avoided, and direct connection
to the MKS-8080/8082 is possible.
A simple connection is possible if the following conditions
are met:
• There are no devices other than the control panel and
MKS-8080/8082 connected on the S-Bus data link.
• There are no more than 16 MKS-8080/8082 units
connected on the S-Bus data link.
To carry out simple connection of the MKS-8080/8082
AUX Bus Remote Panel, use the following procedure.
For settings on the MKS-8080/8082, see the section
"Making the Setting With Buttons (Setup Function)" in the
Operation Manual for the MKS-8080/8082.
1
Initialize the MKS-8080/8082 settings.
This can be executed on the MKS-8080/8082
separately.
2
Set the MKS-8080/8082 station number in the range 2
to 17.
This can be set on the MKS-8080/8082 separately.
3
Set the S-Bus data link primary station to the control
panel by setting the STATION ID switches on the
front of the board in the MVS-3000 SLOT 8 to 001
(switch 1 only to the OPEN position).
288

Simple Connection of the MKS-8080/8082 AUX Bus Remote Panel

Double-press Menu
KEY1
• M/E-1 >Key1 >XX
• PGM/PST >DSK1 >XX
KEY2
• M/E-1 >Key2 >XX
• PGM/PST >DSK2 >XX
KEY3
• M/E-1 >Key3 >XX
• PGM/PST >DSK3 >XX
KEY4
• M/E-1 >Key4 >XX
• PGM/PST >DSK4 >XX
Flexi Pad
System control unit Board
MVS-3000
4
In the Engineering Setup >System >Initialize menu
(7315), select PNL, and carry out a reset.
This carries out a restart, and when the restart is
completed connection to the MKS-8080/8082 is
possible.
5
In the Engineering Setup >Router/Tally >Router menu
(7361), set the position of the MVS-3000 system in S-
Bus space.
Select the setting of SWR1, and set each of Source,
Destination, and Level to 1.
Setting Status of the MKS-8080/8082
in Simple Connection
As a result of making the simple connection, the MKS-
8080/8082 operates in AUX bus mode, and the settings are
the following factory defaults.
With regard to the meaning of the following settings, see
the section "Menu Operations" in the Operation Manual
for the MKS-8080/8082.
C: SET SWITCHER ID (for AUX mode)
This is set to 001, which is the station number of the
control panel.
D: SET AUX DESTINATION/SOURCE (for AUX
mode)
The source is set to IN001 and following, and destination
is set to OUT001 and following.
H: SET PHANTOM TABLE (for Router mode)
Not set, as unit does not operate in router mode.
N: SET PANEL TABLE (for Router mode)
The source is set to IN001 and following, and destination
is set to OUT001 and following. However, since the unit
Refer to
p. 64
STATION ID
switches
CA-85
S3801