Simple Connection of the
MKS-8080/8082 AUX Bus
Remote Panel

Procedure for Simple Connection

To connect the MKS-8080/8082 AUX Bus Remote Panel
to a system interface unit (SIU) using an S-Bus data link
requires an HKSP-R80 Routing Switcher Controller Board
or similar primary station and various settings for
connection.
However, when using a simple connection, the need for an
S-Bus data link primary station is avoided, and direct
connection to the MKS-8080/8082 is possible.
A simple connection is possible if the following conditions
are met:
• There are no devices other than the SIU and MKS-8080/
8082 connected on the S-Bus data link.
• There are no more than 16 MKS-8080/8082 units
connected on the S-Bus data link.
To carry out simple connection of the MKS-8080/8082
AUX Bus Remote Panel, use the following procedure.
For settings on the MKS-8080/8082, refer to the "Making
the Setting with Buttons (Setup Function)" section and
"Setting the station number" in "Preparations for the
MKS-8080/8082" section in the Operation Manual for the
MKS-8080/8082.
1
Carry out initialization of the MKS-8080/8082
settings.
This can be executed on the MKS-8080/8082
separately.
2
Set the MKS-8080/8082 station number in the range 2
to 17.
This can be set on the MKS-8080/8082 separately.
3
Set the S-Bus data link primary station to the SIU by
setting the STATION ID switches on the front of the
board in SLOT 1 of the SIU to 001 (switch 1 only to
the ON position).
System Interface Unit Board
MKS-X2700/X7700
When finished, reboot the SIU (power off and then on
again).
STATION ID
switches
CA-90
S3801
4
In the Engineering Setup >Router/Tally >Router menu
(7361), set the position in the XVS-8000 system S-Bus
space.
Select the setting from SWR1 and SWR2, and set each
of Source, Destination, and Level to 1.
Setting Status of the MKS-8080/8082
in Simple Connection
As a result of making the simple connection, the MKS-
8080/8082 operates in AUX bus mode, and the settings are
the following factory defaults.
With regard to the meaning of the following settings, refer
to the "Menu Operations" section in the Operation Manual
for the MKS-8080/8082.
C: SET SWITCHER ID (for AUX mode)
This is set to 001, which is the station number of the SIU.
D: SET AUX DESTINATION/SOURCE (for AUX
mode)
The source is set to IN001 and following, and destination
is set to OUT001 and following.
H: SET PHANTOM TABLE (for Router mode)
This is not set, since the unit does not operate in router
mode.
N: SET PANEL TABLE (for Router mode)
The source is set to IN001 and following, and destination
is set to OUT001 and following. However, since the unit
does not operate in router mode, these settings are not
used.
O: SET AVAILABLE SOURCE/DESTINATION
Set the source and destination ranges so that the XVS-8000
inputs and outputs can be selected.
R: SET ROUTE
Since when using the simple connection the switcher and
router cannot be connected in cascade, no route setting is
required, and this is not set.
Y: SET DISPLAY MODES
The DISPLAY MODES/PANEL FUNCTION setting is
set to NORMAL.
The TALLY GROUP settings match the settings in the
Engineering Setup >Router/Tally >Group Tally menu
(7362).
Z: SET PANEL STATUS
The various settings are the same as the factory default
settings.