Auto-Cost Reference-Bandwidth (Ipv) - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604
m
auto-cost reference-bandwidth (IPv6)
auto-cost reference-bandwidth MBPS
no auto-cost reference-bandwidth
Syntax Description
MBPS
Default
Command Mode
Usage Guideline
Examples
Switch > enable
Switch # configure terminal
Switch (config) # router ipv6 ospf
Switch (config-router)# auto-cost reference-bandwidth 1000
CLI Reference Guide
To control the reference value IPv6 OSPF uses when calculating metrics for
interfaces, use the auto-cost reference-bandwidth command. To return the
reference value to its default, use the no form of this command.
MBPS Rate in Mbps bandwidth. The range is from 1 to 4294967. The default is
100.
MBPS: 100.
Router configuration
The IPv6 OSPF metric is calculated as the Mbps value divided by the bandwidth,
with Mbps equal to 100 by default, and bandwidth determined by the bandwidth
command. The calculation gives Fast Ethernet a metric of 1.
The following example sets the auto-cost reference bandwidth to 1000 Mbps.
auto-cost reference-bandwidth (IPv6)
56

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dgs-6604Dgs-6600 series

Table of Contents