startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first
cflash-cap-warn
Syntax
cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold] interval
no cflash-cap-warn cflash-id
Context
config>system>thresholds
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode
Description
This command enables capacity monitoring of the compact flash specified in this command.
The severity level is warning. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold warning.
Parameters
cflash-id — Specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. A single
3HE 17358 AAAB TQZZA
none — No action is taken.
Default
both
created.
If the first sample is greater than or equal to the rising threshold value and startup-
alarm is equal to rising or either, a single rising threshold crossing event is
generated.
If the first sample is less than or equal to the falling threshold value and startup-
alarm is equal to falling or either, a single falling threshold crossing event is
generated.
Default
either
Values
rising, falling, either
seconds [rmon-event-type] [startup-alarm alarm-type]
Values
uf1: (7210 SAS-M)
cf1:, cf2:, uf1: (7210 SAS-T, 7210 SAS-Sx 1/10GE: standalone and
standalone-VC, 7210 SAS-Sx 10/100GE, and 7210 SAS-Mxp)
cf2:, cf2-A:, cf2-B:, uf1:, uf1-A:, uf1-B: (7210 SAS-R6 and
7210 SAS-R12)
cf1:, cf2: (7210 SAS-S 1/10GE: standalone and standalone-VC)
threshold crossing event is generated when the current sampled value is greater than
or equal to this threshold, and the value at the last sampling interval was less than
this threshold. A single threshold crossing event will also be generated if the first
sample taken is greater than or equal to this threshold and the associated startup-
alarm is equal to rising or either.