1 Alarms
Reactions:
Remedy:
Program Continuation:
4003
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4004
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-26
- Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
Check and correct either
• $MC_GEOAX_ASSIGN_TAB
• $MC_TRAFO_AXES_IN_X
• $MC_TRAFO_GEOAX_ASSIGN_TAB_X
• $MC_FGROUP_DEFAULT_AXES
• and/or $MC_AXCONF_MACHAX_USED.
Switch control OFF - ON.
Axis %1 incorrect assignment of master channel in machine data %2
%1 = Axis
%2 = String: MD identifier
For some applications, it is useful to operate an axis in several channels (C axis or spindle
on single spindle or double carriage machines).
The machine axes which are defined in several channels by means of the MD 20070
AXCONF_MACHAX_USED, must be assigned to a master channel with the axis-specific
machine data 30550 AXCONF_ASSIGN_MASTER_CHAN.
For axes that are activated in only one channel, the number of this channel or zero must
be entered as master channel.
- Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Modify MD 20070:
AXCONF_MACHAX_USED and/or MD 30550: AXCONF_ASSIGN_MASTER_CHAN.
Switch control OFF - ON.
Channel %1 machine data %2 axis %3 defined repeatedly as geometry axis
%1 = Channel number
%2 = String: MD identifier
%3 = Axis index
An axis may only be defined once as a geometry axis.
- Alarm display.
- Interface signals are set.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Correct $MC_GEOAX_ASSIGN_TAB.
Switch control OFF - ON.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved