11.02
Remedy:
Program Continuation:
16794
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16795
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16796
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16797
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Modify part program. Switch off coupling(s) of this axis before changing transformation or
do not change the transformation.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 coupling of axis/spindle %3 prohibits reference point
approach
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
The specified axis is a (gantry) slave axis and cannot therefore approach the reference
point.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program. Switch off coupling(s) of this axis before reference point approach or
do not reference. A gantry slave axis cannot reference for itself.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 string cannot be interpreted
%1 = Channel number
%2 = Block number, label
A coupling has been switched on in which a non-interpretable string has been written (e.g.
block change behavior).
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 coupling not defined
%1 = Channel number
%2 = Block number, label
A coupling is to be switched the parameters of which have neither been programmed nor
configured.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department. Correct NC part program or
MD, program the coupling with COUPDEF or configure by means of MD.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 coupling is active
%1 = Channel number
%2 = Block number, label
An operation is to be performed in which no coupling may be active, e.g. COUPDEL or
TANGDEL must not be used on active couplings.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.