Bosch PSI 6XXX.350 L1 Series Technical Information page 79

Timer and i/o level
Table of Contents

Advertisement

Electrical connection
<Control ready>
7-38
The <Control ready> signal indicates the ready status of the weld timer. At the same
time, the green LED ⇑ lights up. This signal is cleared in the event of a fault, e.g. with:
-
E-STOP circuit open
-
a fault in the [Sequence] or a non-permitted deviation in a monitored value that has
been defined as a fault in the Fault Allocation in the Basic Setup menu.
-
a battery fault that has been defined as a fault in the Fault Allocation in the Basic
Setup menu, etc.
Cf. page 10-3: Messages concerning the timer status, page 10-4: Messages con-
cerning current and time monitoring.
NOTE
The programming terminal signals the cause of the fault in the Timer Status Message
window. Detailed information is displayed by calling up diagnostics for I/Os or timer diag-
nostics.
When the cause of the fault has been cleared, the ready state is restored by:
-
the <Reset Fault> signal, cf. page 7-18
-
the <Fault reset with WC> signal, cf. page 7-18
-
the <Fault reset with reweld> signal, cf. page 7-18
-
an operation in the BOS-5000 software, e.g. in the Diagnostics - Timer window.
-
using the reset push button on the front panel, cf. page 3-2.
PSI 6XXX.350 L1
1070 080 067-101 (2001.03) GB

Advertisement