[1]
Diagnostics messages of INTERBUS-S:
-
TR
Transmit/Receive, shows PCP communication.
-
CC
Cable Check, the green LED indicates that the optical waveguide is properly
connected to the input. When the INTERBUS-S master module is reset, the
LED goes off.
-
BA
Bus Active, the green LED indicates that INTERBUS-S data transmission is
active.
-
FO1
Message "F01 IN Interface o.k." Yellow LED.
-
UL
Unit Supply, the green LED indicates that the supply voltage is available at
the bus drop.
-
RD
Remote Disable, the red LED indicates that the downstream optical wave-
guide has been switched off.
-
FO2
Message "F02 OUT Interface o.k." Yellow LED.
[2]
Connection of optical waveguide IB-S-IN
(output from timer)
[3]
Connection of optical waveguide IB-S-IN
(input to timer)
[4]
Connection of optical waveguide IB-S-OUT
(output from timer)
[5]
Connection of optical waveguide IB-S-OUT
(input to timer)