PSI 6XXX.350 L1
Electrical connection
NOTE
If electrode number 0 is selected with the <Spot selection> signals and an <Acknowl-
edge Tip change> signal becomes high, the tip dress and wear counters of all elec-
trodes are reset.
If an electrode number 1 through n (n = maximum number of electrodes) is selected with
the <Spot selection> signals and an <Acknowledge Tip change> signal becomes
high, the tip dress and wear counters of the electrode selected with the signals for <Spot
selection> are reset.
If electrode number 0 is selected with the <Spot selection> signals and a <Tip dressed>
signal becomes high, the tip dress counters of all electrodes are incremented and the
wear counters are set to a defined value.
If an electrode number 1 through n (n = maximum number of electrodes) is selected with
the <Spot selection> signals and a <Tip dressed> signal becomes high, the tip dress
counter is incremented by 1 and the wear counter is set to a defined value for the elec-
trode selected by the number of the <Spot selection> signals.