9 | CAN Bus
9.2.5 Conversion to physical values
9.2.6 Special features
30 / 108
a) Enter name of the CAN-channel.
b) Enter CAN message ID. Check the box, if extended IDs (29 bit) are used.
c) If replacement values are used, specify time-out period and raw value.
d) Check the box, if a multiplexer (row counter) is used.
e) Enter data position, length and format. The matrix table shows the assignment of the bits.
f) Enter a Conversation to get physical values
a) Enter factor (gain) for conversion to physical value.
b) Enter offset for conversion to physical value.
c) Select type of physical value.
d) Select unit of physical value.
e) Enter minimum physical limit of the channel. (for manual setup)
f) Enter maximum physical limit of the channel. (for manual setup)
g) Check the box to automatically adjust the limits of the channel.
CAN analyzer functionality
This functionality is only available, if a MSA-Box (I & II) is used to connect the C 60 to the
PC. Choose the CAN bus that is connected to the MSA-Box to display the raw value and
the converted physical value here.
Data Logger C 60