8.2 Feature activation

– Optional software feature packages are available for the C 60 If you have purchased
an optional software feature package, it must be activated before it becomes opera-
tional.
– The feature activation status is stored permanently in the device and requires activat-
ing once only.
– As the activation key is device specific, a key delivered with one C 60 does not work
on any other C 60 .
– If you have not purchased an option package, the next steps can be skipped.
To activate a feature, double-click on 'C 60' in the Project Tree and click on the 'Features
info' tab in the Main Area.
The 'C 60 features info' window appears.
Double-click on the feature you want to activate. A feature unlock window appears.
Enter the activation key you received for this feature on this device and click 'OK' when
done. The feature's status changes to 'unlocked'.
Perform these steps to activate other features you purchased.
Switch the car's ignition off and on again to cycle the power of C 60.

8.3 First recording (Quick start)

This chapter explains the configuration of the recording of the battery voltage channel.
See chapter 'Recording and Telemetry [} 79]' for a detailed instruction to configure re-
cordings.
This function requires the installation of Software Upgrade 1. For data recording on the C
60 , the software upgrade 'C 60 Datalogger' must be activated. See chapter 'Feature activ-
ation' for an instruction to activate software upgrades on C 60.
1.
Expand the C 60 Project Tree by clicking '+'.
2.
Expand the Logger Tree by clicking '+'.
3.
Double-click on 'Recording'.
4.
The C 60 recording configuration area opens.
In C 60 Project Tree, click on 'C 60' to display the available measurement channels. In the
data window, scroll down to 'ub' (measurement channel for battery voltage).
Drag + drop the 'ub' measurement channel into the recording area.
Right-click on 'C 60' in the C 60 Project Tree and choose 'Download configuration'.
The configuration download starts and the C 60 carries out a reset.
1.
As we did not define global start conditions, recording starts immediately.
2.
Start the WinDarab software.
3.
Disconnect the C 60 network cable.
4.
Click on the 'Import/Export' icon.
Data Logger C 60
Starting up the C 60 | 8