Siemens MICROMASTER 440 Operating Instructions Manual page 271

0.12kw-250kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 10/06
Input voltage range
(Unfiltered)
Order No.
Output Rating (CT)
Output Power
CT Input Current 1)
CT Output Current
VT Input Current 1)
VT Output Current
Recommended Fuse
Pipe cable shoe to
DIN 46235
Input Cable Min.
Input Cable Max.
Output Cable Min.
Output Cable Max.
Weight
1) Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
voltage of 400 V without line commutating reactor.
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
6SE6440- 2UD38-8FA1 2UD41-1FA1 2UD41-3GA1 2UD41-6GA1 2UD42-0GA1
[kW]
90
[hp]
125
[kVA]
145.4
[A]
169
[A]
178
[A]
205
[A]
205
[A]
250
3NE
1227-0
[mm]
10
2
[mm
]
1 x 95 or
2 x 35
[awg] or
1 x 4/0 or
[kcmil]
2 x 2
2
[mm
]
1 x 185 or
2 x 120
[awg] or
1 x 350 or
[kcmil]
2 x 4/0
2
[mm
]
1 x 95 or
2 x 35
[awg] or
1 x 4/0 or
[kcmil]
2 x 2
2
[mm
]
1 x 185 or
2 x 120
[awg] or
1 x 350 or
[kcmil]
2 x 4/0
[kg]
110
[lbs]
242
≥ 2.33 % referred to the rated drive converter power and a rated line supply
k
5 MICROMASTER 440 specifications
3 AC 380 V – 480 V ± 10 %
110
132
150
200
180
214.8
205
245
205
250
245
297
250
302
315
400
1230-0
1332-0
10
10
1 x 150 or
1 x 185 or
2 x 50
2 x 70
1 x 300 or
1 x 400 or
2 x 1/0
2 x 2/0
1 x 185 or
2 x 240
2 x 120
1 x 350 or
2 x 400
2 x 4/0
1 x 150 or
1 x 185 or
2 x 50
2 x 70
1 x 300 or
1 x 400 or
2 x 1/0
2 x 2/0
1 x 185 or
2 x 240
2 x 120
1 x 350 or
2 x 400
2 x 4/0
116
170
256
375
160
200
250
300
263.2
339.4
297
354
302
370
354
442
370
477
450
560
1333-0
1435-0
10
10
1 x 240 or
2 x 95
2 x 70
1 x 500 or
2 x 4/0
2 x 2/0
2 x 240
2 x 240
2 x 400
2 x 400
1 x 240 or
2 x 95
2 x 70
1 x 500 or
2 x 4/0
2 x 2/0
2 x 240
2 x 240
2 x 400
2 x 400
174
176
384
388
271