Issue 10/06
Correspondingly, the Response IDs are transferred in the telegram from the slave
to the master at this position. Depending on the request ID, only specific response
IDs are possible.
Table 3-20
Response
ID
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
The required element of the parameter description is specified in IND (2nd word)
2
The required element of the indexed parameter is specified in IND (2nd word)
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
Response ID (converter -> master)
Significance
No response
Transfer parameter value (word)
Transfer parameter value (double word)
Transfer descriptive element
Transfer parameter value (array, word)
Transfer parameter value (array, double word)
Transfer the number of array elements
Request cannot be executed (with fault number)
The PKW interface does not have master authority
Parameter change report (word)
MICROMASTER does not support this
Parameter change report (double word)
MICROMASTER does not support this
Parameter change report (array, word)
MICROMASTER does not support this
Parameter change report (array, double word)
MICROMASTER does not support this
Reserved
Reserved
Transfer text
MICROMASTER does not support this
1
2
2
2
2
3 Functions
Request
ID
0
1, 2 or 14
1, 3 or 13
4 or 5
6, 7 or 12
6, 8 or 11
9
1 or 15
2, 3, 5, 7, 8,
11-14 or 15
-
-
-
-
-
-
15
159