Siemens MICROMASTER 440 Operating Instructions Manual page 220

0.12kw-250kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

3 Functions
Motor
lin
Motor
rot
Fig. 3-86
Rotary or linear axis
Using this data, MICROMASTER 440 calculates the ratio between the distance
and the motor revolutions and can therefore consider the movement on the load
side.
NOTE
When the positioning down ramp is enabled using parameter P0500 = 3, then
implicitly the control mode P1300 is reset as follows as a function of parameter
P0205:
a) P0205 = 0
b) P0205 = 1
This change can be undone again after the positioning down ramp has been
enabled by modifying parameter P1300.
220
Disposition
s
lin
Load
Gear
z
Ü
n
n
Motor
Load
Gear
s
Ü
n
n
Motor
Load
P1300 = 0
P1300 = 2
Parameter
Motor revolutions
Ü =
Load revolutions
z = screw spindle =
Motor revolutions
Ü =
rot
Load revolutions
MICROMASTER 440
Issue 10/06
P2481
=
P2482
No. of revolutions
= P2484
1 [unit]
P2481
=
P2482
Operating Instructions
6SE6400-5AW00-0BP0