MULTI-CELL SYSTEM SETUP
Configure Level 1 Base
Stations
Figure 1-20 Multi-cell Screen (top) after Configuration
IP4100 Install Sept., 2013
1. Place the first Level 1 base station at its final location.
2. Login to the Level 1 base station.
3. Reset the base station to its default settings (open the Management
screen and click Default Base Station). If this base station has never
been configured, skip this step.
4. Go to the Multi-cell screen and set the Multi cell system field to
Enable.
5. Enter the System chain ID of the chain this base station will belong to.
6. If you want the base station to include low level multi cell debug
information in the System Log, set the Multi cell debug field to Data
Sync, Auto Tree, or Both.
Note:
This log contains a large number of messages, so you should
leave it disabled most of the time.
7. Click Save and reboot the base station (go back to the Home/Status
screen and click Reboot).
8. When the base station finishes rebooting, click Home, and after a few
minutes, go back to the Multi-cell screen. You will see that the System
chain ID field is read-only, and the DECT system settings and Base
station settings fields, and the Base Station Group table are added to
the bottom of the screen.
9. Keep the Auto configure DECT sync source tree set to Disabled.
10. In the Number of SIP accounts before distributed load field, enter the
maximum number of handset registrations (up to 30) for each base
station. This number is synchronized among all the bases in the
chain, so you only have to enter it once.

Configure Level 1 Base Stations