Checking the thermoswitch
1. Place the thermoswitch in a container of
water and slowly heat the water.
2. Check the switch for continuity at the
specified temperatures. Replace if out of
specification.
a Temperature
b Time
c No continuity
d Continuity
Thermoswitch continuity
temperature:
Pink (P) – Black (B)
e: 84–90 °C (183–194 °F)
f: 68–82 °C (154–179 °F)
69J1D11
Ignition and ignition control system
Checking the shift cut switch
1. Check the shift cut switch for continuity.
Replace if there is no continuity.
S69J8250
Free a
Push b
Checking the neutral switch
1. Check the neutral switch for continuity.
Replace if there is no continuity.
Free a
Push b
Lead color
Switch
Blue/yellow
position
(L/Y)
Lead color
Switch
position
Brown (Br)
1
2
S69J8270
3
Black (B)
4
5
6
S69J8270
7
Black (B)
8
9
8-14