6.3
Firmware Updating with FSMS (Field Service Manager)
(e-STUDIO350/450)
In this equipment, it is feasible to update the downloaded firmware from the PC connected with the
equipment by using the utility software"FSMS (Field Service Manager)". Firmware can be also down-
loaded through USB, in addition to an existing serial transfer through RS-232C.
This chapter explains only the firmware downloading method with FSMS. Refer to the Field Service
Manager Operator's Manual for the details about installation method and functions of FSMS.
OS:
Windows 98
Windows Me
Windows NT4.0
Windows 2000
Windows XP
Important:
Updating with USB connection is more recommended since the data transfer speed is lower
and it takes more time to update in the serial connection with RS-232C cable.
Example:
*
The updating time noted above is a reference. It may vary depending on the performance
of the PC used.
Updating through USB is not feasible for Windows NT4.0 since this operating system does
not support USB. When this system is used, update in the serial connection with RS-232C
cable.
When updating through USB (using FSMS), a printer driver needs to be installed in the PC in
advance. Refer to the Printing Guide about the installation method of the printer driver.
e-STUDIO350/352/353/450/452/453
FIRMWARE UPDATING
Connecting cable:
USB cable or
RS-232C cable
PC:
IBM PC/AT or compatible machine
(USB port or RS-232C port is needed)
Fig. 6-64
Updating time for system ROM (sysfirm.tz: Approx. 8 MB)
RS-232C connection: Approx. 1 hour and 20 minutes
USB connection: Approx. 10 minutes
6 - 66
06/01
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved