2.2.3
Output check (test mode 03)
Status of the output signals can be checked by entering the following codes in the test mode 03.
<Operation procedure>
Procedure 1
[0][3]
(Code)
[START]
[POWER]
Procedure 2
[0][3]
(Code)
[POWER]
Procedure 3
[0][3]
(Code)
[START]
[POWER]
Procedure 4
[0][3]
(Code)
[POWER]
Code
Function
101
Main motor ON (operational without
developer unit)
102
Toner motor ON (normal rotation)
103
Polygonal motor ON (600 dpi)
108
Registration clutch ON
109
PFP motor ON
110
ADU motor ON
118
Laser ON
120
Exit motor ON (normal rotation)
121
Exit motor ON (reverse rotation)
122
LCF motor ON
177
Offset Tray motor ON (reciprocating movement)
201
Upper drawer feed clutch ON/OFF
202
Lower drawer feed clutch ON/OFF
203
Transport clutch (high speed) ON/OFF
204
Bypass feed clutch ON/OFF
205
Transport clutch (low speed) ON/OFF
206
LCF pickup solenoid ON/OFF
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
Operation
ON
code
Operation
[START]
One direction
Operation
[START]
ON
[POWER] OFF
[START]
Code
151
152
153
158
159
160
168
170
171
172
Stop
Operation
[START]
OFF
Test mode
[CLEAR]
standby
Operation
[CLEAR]
OFF
Function
Code No.101 function OFF
Code No.102 function OFF
Code No.103 function OFF
Code No.108 function OFF
Code No.109 function OFF
Code No.110 function OFF
Code No.118 function OFF
Code No.120 function OFF
Code No.121 function OFF
Code No.122 function OFF
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
2 - 42
05/12
[POWER] OFF/ON
(Exit)
[POWER] OFF/ON
(Exit)
[POWER]
Test mode
OFF/ON
standby
(Exit)
Procedure
1
1
1
1
1
1
1
1
1
1
2
3
3
3
3
3
3

Hide quick links: