3.12.3

Adjusting the overlap of the sensor flag

If the overlap between the sensor and the flag is wrong for some reason, perform the following adjust-
ment.
(1)
Remove the processing tray unit.
(2)
Loosen the mounting screw of the front/rear jogging plate adjusting plate; then, move the adjust-
ing plate to the left and the right.
(3)
Tighten the screw so that the overlap between the flag of the front/rear jogging rack plate and the
sensor is 1.5 mm to 2.0 mm.
e-STUDIO350/352/353/450/452/453
ADJUSTMENT
Jogging plate
adjusting plate
Screw
Screw
Adjusting plate
Fig. 3-120
Sensor
1.5 mm to 2.0 mm
Fig. 3-121
Jogging plate
Adjusting plate
adjusting plate
Sensor flag
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved