Setting file
An example of the setting file for this utility is shown below.
[General]
IgnoreCommands=Off
SystemParam00=49,0
SystemParam01=&32,&f7
[MSR]
Beep=On
CodeType=US
ValidTracks=1,2,3,J
CodeDefinition00=48,10
CodeDefinition01=&31,11,Shift
CodeDefinition02=&32,&0A,Ctrl
CardStart=CS
CardEnd=CE
Track1Start=1S
Track1End=1E
Track2Start=2S
Track2End=2E
Track3Start=3S
Track3End=3E
JIS2Start=JS
JIS2End = JE
In the General section, an entry line that may affect the entirety is described, in principle.
IgnoreCommands may be specified to be On. When it is specified to be On, the setting of the
keyboard or MSR cannot be read or written.
SystemParamxx is described when the data is written in the system conversion area. The
offset and data of the variable are divided with [,] for specification. These two can be
specified by the byte width in the form of decimal or hexadecimal or character. For the
decimal specification, it is described as it is. For the hexadecimal specification, & should be
prefixed. For the character, $ should be prefixed. SystemParamxx may be described in more
than one file by describing decimal in xx from 00 in order up to 99.
In the MSR section, an entry that is related to the MSR is described.
Beep may be specified to be On or Off. When it is specified to be On, beep sounds while the
MSR is being read. When it is specified to be Off, beep does not sound while the MSR is
being read.
CodeType is specified to be US, JP, FR, GR, or SP. The key-in data created while the MSR
was being read becomes conformable to the keyboard array of the specified country.