7 - 34 RS507 Product Reference Guide

Reconnecting

Automatic reconnection
The RS507 maintains BT communication with the connected device within a range of 10 meters (30 feet). When
the RS507 fails to establish connection or connection is lost during operation:
The RS507 emits one string of low/high beeps.
The RS507 automatically attempts to reconnect to the computer for 30 seconds (the Scan LEDs flash
green).
Manual reconnection to Restore Lost Bluetooth Connection
If automatic re-connection fails, verify that the RS507 is within BT range and briefly press the small Restore key on
the side of the RS507 to reconnect.
The RS507 Scan LEDs start to flash green, indicating that the RS507 is attempting to establish connection
with the computer.
The Scan LEDs turn off and the RS507 emits one string of low/high beeps indicating that the RS507 is
connected and ready for scanning.
NOTE When the RS507 is in SPP connection mode, pressing the Restore key after a Warm or Cold boot
reconnects the RS507 to the last paired device. Connection is established as long as the link key on the
device side is not deleted (the authentication key used to establish a link between devices).

How to demonstrate SPP connection with a computer

Once SPP connection is established, an application is required to demonstrate the RS507.
To scan a bar code:
If the RS507 is still connected to the PC Tool application, close the COM port on the PC Tool application.
1.
Run a hyper terminal application such as the Tera Term application.
2.
(http://www.ayera.com/teraterm/download.cfm).
Tera Term Application Screen
Figure 7-45
Select the virtual COM port set for the RS507 connection.
3.
 

Hide quick links: