The following diagrams show how the jump point is selected. The diagram on the left shows a
sequence in which the jump takes place at the end of the area to be jumped, for which the lower
frequency must be entered in parameter 31 "Frequency jump 1A". In the diagram on the right the
jump takes place at the beginning of the frequency area to be jumped, for which the higher fre-
quency must be entered parameter 31 "Frequency jump 1A".
Fig. 6-58: Selection of the jump point
NOTE
During acceleration/deceleration, the running frequency within the set area is valid.
FR-A700 EC
Hz
38
32
Set frequency
Hz
38
Pr.32 (1B)
Pr.31 (1A)
32
Limit the output frequency
Pr.31 (1A)
Pr.32 (1B)
Set frequency
I00019aC
6 - 171