Sony PMW-10MD Operating Instructions Manual page 4

Hd video camera
Hide thumbs Also See for PMW-10MD:
Table of Contents

Advertisement

mains via an additional isolation
transformer conforming with the
construction requirements of IEC60601-
1 and providing at least Basic Insulation.
5. This equipment generates, uses, and
can radiate radio frequency energy. If it is
not installed and used in accordance with
the instruction manual, it may cause
interference to other equipment. If this
unit causes interference (which can be
Important EMC notices for use in the medical environments
• The PMW-10MD needs special precautions regarding EMC and needs to be installed and put
into service according to the EMC information provided in this instructions for use.
• The portable and mobile RF communications equipment such as cellular phones can affect the
PMW-10MD.
List of cables used for EMC tests
Type of cable
Power Supply Cord
CCMC-T20 camera cable
BNC Cable
RGB Cable
DVI-D Cable
S-Video Cable
D-Sub 9P Cable (RS232C)
Warning
The use of accessories and cables other than those specified, with the exception of replacement
parts sold by Sony Corporation, may result in increased emissions or decreased immunity of the
PMW-10MD.
Guidance and manufacturer's declaration - electromagnetic emissions
The PMW-10MD is intended for use in the electromagnetic environment specified below.
The customer or the user of the PMW-10MD should assure that it is used in such an environment.
Emission test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
4
Specifications
2.4 m, non-shielded
20 m, shielded
2 m, shielded
3 m, shielded
2 m, shielded
2 m, shielded
3 m, shielded
Compliance
Group 1
The PMW-10MD uses RF energy only for its internal
function. Therefore, its RF emissions are very low and
are not likely to cause any interference in nearby
electronic equipment.
Class B
The PMW-10MD is suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supply
network that supplies buildings used for domestic
Class A
purposes.
Complies
determined by unplugging the power
cord from the unit), try these measures:
Relocate the unit with respect to the
susceptible equipment. Plug this unit and
the susceptible equipment into different
branch circuit.
Consult your dealer. (According to standard
EN60601-1-2 and CISPR11, Class B,
Group 1)
Electromagnetic environment-guidance