Divar 700 Series
6.4
Recording
Use the Recording menu to configure the recording set-up for each of the six profiles.
Note:
The audio/video settings in a profile also apply to the stream used for remote live viewing.
Figure 6.10 Configuration menu - Recording - Normal
The recording behavior for each of the six profiles is specified in three submenus and then for
each individual channel.
1.
2.
3.
6.4.1
Normal
Set values for each of the following fields:
–
–
Bosch Security Systems
Select a profile.
Choose an individual input channel to configure the settings for recording its video and
audio.
Select a submenu for Normal, Contact, or Motion recording.
–
Normal recording - the default recording mode
–
Contact recording - activated upon an contact input event
–
Motion recording - activated upon a motion event
Normal recording mode:
–
Continuous - set to record continuously
–
Event only - set to record events only
–
No Recording - set to disable recording
Pre-Event Time:
–
set between 1 and 120 seconds (only applicable when recording Event only). The
recoding for the event starts this amount of time before the event occcurs.
Installation and Operation manual
Advanced configuration | en
F.01U.246.471 | v3.4 | 2011.06
75