9.1

Integrus transmitter

9.1.1

Start-up

When the transmitter is switched on, the display shows the Transmitter Status screen, which
is the first item of the Main menu (see section Main menu, page 51). The display also goes to
this screen after 3 minutes of inactivity. In case the system detects a fault, the display shows a
flashing fault message (see section Fault messages, page 72).
9.1.2

View transmitter status

The first screen of the Main menu gives information about the present status of the
transmitter. The screens shows the name of the transmitter (1st line) and the present
transmission mode (2nd line). See examples below. See section Set transmission (4A), page 52
to change the transmission mode.
Transmitter is transmitting 10
channels from DCN.
Menu Item
Transmitter Status
9.2

Integrus Radiators

A radiator consists of two IRED panels. Each IRED panel has an amber and a red indicator LED
which show the status of the radiator panel
Bosch Security Systems B.V.
Transmitter is transmitting the
Aux inputs on all channels.
Option (read only)
Name
Mode:
- nn Channels
- Aux to All
- nn Ch. Test
- Slave
- Standby
- Emergency Call
DCN
Operation manual
Transmitter is in Standby
mode (not transmitting).
Description
The first line shows the user defined name of
the transmitter (see section Choose
transmitter name (4O), page 58).
The second line shows the actual
transmission mode:
Audio signals are distributed on nn channels.
The signal on the Aux. inputs is distributed on
all channels.
The test signals are distributed on nn
channels.
The transmitter operates in slave-mode: the
radiator signal on the slave input is looped-
through to all radiator outputs.
The transmitter is in stand by mode.
An emergency signal from the Aux. inputs is
distributed to all channels.
The text 'DCN' is shown at the right side of
the second line when a DCN Next Generation
system is connected to the transmitter.
Operation | en