Figure 3.5: LBB 4512/00 Radiator (Side and rear view)
1
2
3
4
5
6
7
Bosch Security Systems B.V.
1
2
Safety eye - To mount a safety cord for extra security.
Safety eye hole - Tapped hole to mount the safety eye.
Bracket hole - Tapped hole to mount the suspension bracket.
Mains input - Male Euro mains connector. The radiators have automatic mains voltage
selection.
IR signal input/loop-through - Two HF BNC connectors for connecting the radiator to
the transmitter and for loop-through connection to other radiators. Automatic cable
termination is achieved by a built-in switch in the BNC connectors.
Output power selection switch - The radiators can be switched between full- and half-
power operation.
Delay compensation switches - Two 10-position switches to compensate for
differences in cable lengths to the radiators.