MIC612 Thermal Camera
Internal Humidity
Displays the percentage of humidity inside the camera housing.
Humidity Events
Displays the number of times that the threshold of the humidity inside the camera housing
was exceeded.
Security Access
Displays the number of times that the locked-command menu is unlocked.
CTFID Access
Displays the number of times that the Configuration Tool is accessed.
Restart Events
Displays the number of restart events.
Power Up Events
Displays the number of power up events.
Low Volt Events
Displays the number of times that the camera dropped below the acceptable voltage limit.
Video Loss Events
Displays the number of time that video was lost.
Thermal Camera Test Pattern
Activates the test pattern mode to verify electronics (the output of the digital data channel)
for the thermal camera.
Option
Off
Ascending ramp A test pattern appears in the analog and digital data channels, to
Vertical
Color bars
Bosch Security Systems, Inc.
Description
(Default setting) No test pattern is available.
allow you verify the output of the digital data channel.
The figure below is a horizontal slice of the complete image; the
pattern repeats 19 times in the complete image.
When displayed on an analog video monitor, and if the AGC mode
is not set to the default value, the pattern may appear differently
than shown here.
Figure 6.1
Slice of complete image (320 x 256 or 640 × 512)
1: (0,0) = 0
2: (639,0) = 639
3: (25,408) (320 models)/(383,25) (640 models) = 16383
4: (25,409) (320 models)/(384,25) (604 models) = 0
.
Installation Manual
On-Screen Display (OSD) Menus (Bosch Protocol) | en
51
F.01U.249.416 | 2.0 | 2012.09