en | On-Screen Display (OSD) Menus (Bosch Protocol)
Rule Setup Submenu
NOTICE!
You can program a total of twelve rules. You must define the inputs and outputs before you
program a rule. See Section 6.7 Alarm Setup, page 46, to configure alarm inputs and outputs.
Exit...
1. Rule 1
2. Rule 2
3. Rule 3
4. Rule 4
5. Rule 5
6. Rule 6
7. Rule 7
8. Rule 8
9. Rule 9
10. Rule 10
11. Rule 11
12. Rule 12
Rule Setup Submenu Choices:
Rule Setup
Displays the status of rules and lets you add new rules or modify an existing rule.
Rule 1-12
Displays the status of a rule on the right side of the menu. Rule status options:
Option
Enabled The rule inputs and outputs are properly defined and the rule is turned on.
Disabled The rule inputs and outputs are defined but the rule is turned off.
Invalid
Empty
Selecting a Rule number provides access to its configuration menu. The Rule # Menu allows
you to configure a rule from previously-defined alarm inputs and outputs. Once an alarm is
configured with valid inputs and outputs, it can be turned on or off (enabled or disabled)
through its configuration menu.
Rule # Choices:
Enabled
Turns the rule on or off after its inputs and outputs have been defined.
YES to enable or NO to disable (default setting)
F.01U.249.416 | 2.0 | 2012.09
Rule Setup...
Enabled
Disabled
Invalid
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Focus / Iris: Select
Description
The rule has a missing or invalid input or output.
(Default setting) The rule has no inputs or outputs defined.
Installation Manual
Rule 1
Exit...
Enabled
YES
Input:
NONE
NONE
NONE
Output:
OSD
Shot 2
Alarm Relay
2 sec
NONE
Right / Left: Select Period Time
Focus / Iris: Select Type