Advertisement

11 Troubleshooting

Power-up (Boot) Error Messages

Adapter BIOS Disabled. No Logical Drives Handled by BIOS
Problem: The adapter BIOS is disabled. (This is not a problem if the BIOS is
intentionally disabled to prevent booting from the adapter.)
Suggested solution: Enable the BIOS by using HP NetRAID Express Tools, as
described in "Run Configuration Utilities" in Chapter 6.
Host Adapter at Baseport xxxxh not Responding
Problem: The BIOS cannot communicate with the firmware on the adapter.
Suggested solutions:
Verify that the adapter card is plugged all the way into its slot.
Moving the adapter card to another slot.
Run diagnostics under HP NetRAID Express Tools to verify that the
adapter card is functioning properly.
No HP NetRAID Adapter
Problem: The BIOS cannot communicate with the firmware on the adapter.
Suggested solutions:
Verify that the adapter card is plugged all the way into its slot.
Try moving the adapter card to another slot.
Run diagnostics under HP NetRAID Express Tools to verify that the
adapter card is functioning properly.
Configuration of NVRAM and drives mismatch
Run View/Add Configuration option of Configuration Utility.
Press any key to enter the Configuration Utility.
Problem: There is a single adapter, and the configuration stored in its NVRAM
does not match the configuration stored in the drives.