Basic and field level test procedures
Hide thumbs Also See for iDEN i930:
Table of Contents

Advertisement

To connect the unit to the R-2660:
1. Ensure the unit is powered off, and then turn on the R-2660.
2. Remove the battery cover and battery from the unit, and insert the reference SIM card.
3. Attach the battery eliminator to the back of the unit.
4. Engage RF.
5. Connect the SMA connector of the RF cable to the RF connector on the battery eliminator.
6. Connect the N-type connector of the RF cable to the R-2660 RF In/Out connector.
7. Attach the power leads on the battery eliminator to the DC power supply.
CAUTION: Be very careful to observe polarity when connecting power to the
!
battery eliminator.
68P80401P03-O
PREPARING FOR FIELD LEVEL TESTING: Connecting an iDEN Unit to the R-2660
Coaxial Cable
&RD[LDO&DEOH
Un i t U n d er T est
8QLW8QGHU7HVW
Battery
%DWWHU\
Eliminator
(OLPLQDWRU
+
WR9GF
5.0 to 12.0 Vdc
Power Supply
3RZHU6XSSO\
Figure 7-1. Typical R-2660 Setup
5)
RF
,Q2XW
In/Out
1W\SH
(N-type)
R-2660
5
Communications
&RPPXQLFDWL R
System
6\VWHP
Analyzer
$QDO\]HU
7-3