Motorola iDEN i930 Field Service Manual page 107

Basic and field level test procedures
Hide thumbs Also See for iDEN i930:
Table of Contents

Advertisement

MECHANICAL PARTS REWORK AND REPAIR: BGA Rework/Repair Procedure
U500 (Javelin)
See Section BGA Rework/Repair ProcedureBGA Rework/Repair Procedure
Top 330ºC - Bottom 100ºC
OK Ind.: From 5 to 20 l/min
Pace
From 3/4 to 8/9
²Use Traces, Bias and/or Ground edges to aid on X/Y placement.
U600 (Tomahawk)
See Section BGA Rework/Repair ProcedureBGA Rework/Repair Procedure
Top 330ºC - Bottom 100ºC
OK Ind.: Min. 10 l/min – Max.20 l/min
Pace
Min. 4/5 – Max. 8/9
²Use Traces, Bias and/or Ground edges to aid on X/Y placement.
U701 (P-CAP)
See Section BGA Rework/Repair ProcedureBGA Rework/Repair Procedure
Top 330ºC - Bottom 100ºC
OK Ind.: Min. 5 l/min – Max.20 l/min
Pace
Min. 3/4 – Max. 8/9
²Use Traces, Bias and/or Ground edges to aid on X/Y placement.
9-10
N-Q07
"R" over J001/J002 will prevent
degradation.
ALIGNMENT
²As per Pedro.
ALIGNMENT
²As per Pedro.
ALIGNMENT
²As per Pedro.
N-P20
None
N-P20
None