spreading over/inside gold contacts/mechanism. No touch ups are allowed (Fill lands with a good
amount of solder to avoid unsolder leads).
Degradation of component material will affect fit and/or function and may cause future failures.
J500 RF Connector
See Section 9.9 - Mechanical Parts Rework ProcedureMechanical Parts Rework Procedure
Top 330ºC - Bottom 100ºC
OK Industries15 l/min
Pace
6/7
²Use Flux Pen Indium-Indalloy NC771 ONLY (Motorola P/N 1185768C01)
J752 Audio Jack
See Section 9.9 - Mechanical Parts Rework ProcedureMechanical Parts Rework Procedure
Top 330ºC - Bottom 100ºC
OK Industries15 l/min
Pace
6/7
J001 (20 Pin Board-to-Flex Connector)
See Section 9.9 - Mechanical Parts Rework ProcedureMechanical Parts Rework Procedure
Top 330ºC - Bottom 100ºC
OK Industries15 l/min
Pace
68P80401P03-O
MECHANICAL PARTS REWORK AND REPAIR: Mechanical Parts Rework Procedure
NOTE
²Use Flux Sparingly
6/7
NOTE
²Tack down a couple of leads if necessary
N-P07
"F" over M502 during Removal
procedure.
"C" over M502/J500 during
Installation Procedure.
N-P20
Modified "F" over J752 during
Installation Procedure.
N-Q07
"J" over J002 during Removal
procedure.
"R" over J002/J001 during
Installation Procedure.