Siemens SICHARGE UC 150 UL Installation And Operation Manual page 97

Plug-in dispenser
Table of Contents

Advertisement

Description
RL34-Output Diode Heatsink Fan Startup Alarm
RL34-Output Diode Heatsink Fan Shutdown Alarm
A24-Selectivity Module Alarm
OL2-Main Trafo PreMAG OL Relay Tripped
F11-DC Output Plus Fuse Blown
F12-DC Output Minus Fuse Blown
HS1-Bridge Rectifier Heatsink Temperature
Derating
HS1-Bridge Rectifier Heatsink Temperature
Shutdown
HS1-Bridge Rectifier Heatsink Thermal Switch
Tripped (80C)
HS2-IGBT Heatsink 1 Temperature Derating
HS2-IGBT Heatsink 1 Temperature Shutdown
HS2-IGBT Heatsink 1 Thermal Switch Tripped
(80C)
HS3-IGBT Heatsink 2 Temperature Derating
HS3-IGBT Heatsink 2 Temperature Shutdown
HS3-IGBT Heatsink 2 Thermal Switch Tripped
(80C)
HS4-Output Diode Heatsink Temperature Derating
HS4-Output Diode Heatsink Temperature Shut-
down
HS4-Output Diode Heatsink Temperature Switch
Tripped (95C)
T1-TS-Main Trafo Heatsink Temperature Derating
T1-TS-Main Trafo Heatsink Temperature Shutdown
T1-TS-Main Trafo Thermal Switch tripped (150C)
SWL-Left Door Opened
SWR-Right Door Opened
Q3-Primary Control Trafo CB Opened
Q4-Primary Peripheral Trafo CB Opened
Installation and Operations Manual | SICHARGE UC 150 UL Plug-in Dispenser
Error
Error
Code
Handling
29
Measure the DC input to the fan
Check for a broken wire or a loose connection
30
Check the relay for damage
Check for a broken wire or a loose connection
31
Check the Selectivity Module settings
Check for a broken wire or a loose connection
33
Check feedback wire between PLC and OL2 for a broken wire or a
loose connection
34
Check F11 for a blown fuse
Ensure that the low voltage microswitch is making contact for each
fuse
35
Check F12 for a blown fuse
Ensure that the low voltage microswitch is making contact for each
fuse
36
Check the air filter for dirt
37
Check the air filter for dirt
38
Check the air filter for dirt
Check connection between TS1 and X41
Check PT1 for a broken wire or a loose connection
39
Check the air filter for dirt
40
Check the air filter for dirt
41
Check the air filter for dirt
Check connection between TS2 and X42
Check PT2 for a broken wire or a loose connection
42
Check the air filter for dirt
43
Check the air filter for dirt
44
Check the air filter for dirt
Check connection between TS3 and X43
Check PT3 for a borken wire or a loose connection
45
Check the air filter for dirt
46
Check the air filter for dirt
47
Check the air filter for dirt
Check connection between TS4 and X44
Check PT4 for a broken wire or a loose connection
48
Check the air filter for dirt
49
Check the air filter for dirt
50
Check the air filter for dirt
Check PT4 for a broken wire or a loose connection
51
Close the cabinet door completely
Switch off the alarm
52
Close the cabinet door completely
Switch off the alarm
53
Check feedback wire between PLC and Q3 for a broken wire or a
loose connection
Check Q3 for damage
54
Check feedback wire between PLC and Q4 for a broken wire or a
loose connection
Check Q4 for damage
OCPP Error
Category
InternalError
InternalError
PowerSwitchFailure
PowerSwitchFailure
OverCurrentFailure
OverCurrentFailure
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
HighTemperature
OtherError
OtherError
OverCurrentFailure
OverCurrentFailure
97