Charging The Current/Power Curve - Siemens SICHARGE UC 150 UL Installation And Operation Manual

Plug-in dispenser
Table of Contents

Advertisement

SICHARGE UC 150 UL Plug-in Dispenser | Installation and Operations Manual
Connection plan
Type
Charging station Dispenser
DC+
-F11
DC-
-F12
PE
PE
L
CB21-2
N
CB21-4
Ethernet
A13
Fiber-optic
A13_P4
13.2 Charging current/power curve
The charging current and the power curve depend on the connected charging station.
Charging current
The following figure shows the progression of the charging current depending on the charging voltage:
Figure 13-1
Charging current UC 150 charging station
116
Outer cable diameter (in / mm)
-F15
0.63 ... 1.10 in / 16 ... 28 mm
-F16
0.63 ... 1.10 in / 16 ... 28 mm
PE
0.51 ... 0.82 in / 13 ... 21 mm
X23-TB1_1
0/35 ... 0.67 in / 9 ... 17 mm
X24-TB1_1
0/35 ... 0.67 in / 9 ... 17 mm
A2
0.27 ... 0.31 in / 7 ... 8 mm
A2_P3
0.12... 0.24 in / 3...6 mm
Description
DC single conductor
DC single conductor
PE single conductor
AC cable
AC cable
Ethernet cable
Multimode glass fiber-optic with
SC socket (Class A Profinet)