Siemens SICHARGE UC 150 UL Installation And Operation Manual page 96

Plug-in dispenser
Table of Contents

Advertisement

SICHARGE UC 150 UL Plug-in Dispenser | Installation and Operations Manual
Description
Low Input Voltage Shutdown
High Output Voltage Warning
High Output Voltage Shutdown
High Output Current Warning
High Output Current Shutdown
K1-Main CONT CTRL OPN Alarm
K1-Main CONT CTRL CLS Alarm
K2-Main Trafo Premag CONT CTRL OPN Alarm
K2-Main Trafo Premag CONT CTRL CLS Alarm
RL11-DC Output + CONT CTRL CLS Alarm
RL11-DC Output + CONT CTRL OPN Alarm
RL12-DC Output - CONT CTRL OPN Alarm
RL12-DC Output - CONT CTRL CLS Alarm
RL13-Fast Discharge CONT CTRL OPN Alarm
RL13-Fast Discharge CONT CTRL CLS Alarm
RL31-Bridge Rectifiers Heatsink Fan Startup Alarm
RL31-Bridge Rectifiers Heatsink Fan Shutdown
Alarm
RL32-IGBT Heatsink 1 Fan Startup Alarm
RL32-IGBT Heatsink 1 Fan Shutdown Alarm
RL33-IGBT Heatsink 2 Fan Startup Alarm
RL33-IGBT Heatsink 2 Fan Shutdown Alarm
96
Error
Error
Code
Handling
8
Measure the level of the input voltage at the AC input breaker
Measure the AC input voltage on the SinePower board
Measure the artifical netural on the SinePower board
Measure the resistance of RY1 and RY2
9
The voltage difference between the phases must not exceed a
tolerance range. The high output voltage can be caused by various
specific events
Repeat the charging process
Check whether the fault persists
10
The voltage difference between the phases must not exceed a
tolerance range. The high output voltage can be caused by various
specific events
Repeat the charging process
Check whether the fault persists
11
The high output current can be caused by various specific events
Repeat the charging process
Check whether the fault persists
12
The high output current can be caused by various specific events
Repeat the charging process
Check whether the fault persists
13
Check the K1 contactor for damage
14
Check the main contactor coil for damage
Check for a broken wire or a loose connection
15
Check the K2 contactor for damage
16
Check the transformer premag contactor coil for damage
Check for a broken wire or a loose connection
17
Check for damage on R11
Check for damage on K11 contactor coil
Check for a broken wire or a loose connection
18
Check the K11 contactor for damage
19
Check the K12 contactor for damage
20
Check for damage on R12
Check for damage on K12 contactor coil
Check for a broken wire or a loose connection
21
Check the K13 contactor for damage
22
Check for damage on R13
Check for damage on K13 contactor coil
Check for a broken wire or a loose connection
23
Measure the AC input to the fan
Check for a broken wire or a loose connection
24
Check the relay for damage
Check for a broken wire or a loose connection
25
Measure the AC input to the fan
Check for a broken wire or a loose connection
26
Check the relay for damage
Check for a broken wire or a loose connection
27
Measure the AC input to the fan
Check for a broken wire or a loose connection
28
Check the relay for damage
Check for a broken wire or a loose connection
OCPP Error
Category
Undervoltage
Overvoltage
Overvoltage
OverCurrentFailure
OverCurrentFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
PowerSwitchFailure
InternalError
InternalError
InternalError
InternalError
InternalError
InternalError