Digital Discussion System
Problem
Poor web browser
performance.
The tablet, laptop or PC loses
the connection with the
control unit.
Part of system not working
correctly.
The external SDI video
switcher does not switch
between inputs.
Bosch Security B.V.
Possible cause
Multiple users are logged into
the same web browser.
Activating or deactivating
the fixed IP address in
the web browser
interface.
Changing the hostname.
Interrupted system cabling.
Switcher has incorrect
settings.
Operation manual
Troubleshooting | en
Possible solution
automatically record files
to the internal memory
instead.
Replace the (faulty) USB
memory stick.
Make sure only one user is
logged into a web browser. If
multiple users need to log in
at the same time:
use a different browser
type for each user, or
log in using a separate
device (tablet, laptop or
PC).
Close and then reopen the
web browser interface.
Check all trunk
connections between the
Discussion Devices and
the Control Unit.
Check the connections
of the auxiliary
equipment.
Reset the switcher to factory
defaults. Then set the TCP
connection port number.
For the Kramer MV‑6
switcher, set the TCP
connection port number
to 5000.
For the
tvOne CORIOmatrix
switcher, set the TCP
connection port number
to 10001.