SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE
Critical parametrization error: BMS voltage out of range
Fault
BMS
Shutdown routine 3
ETechAcknowledge
BMS voltage actual value invalid
Check the BMS information
Critical parametrization error: BMS SOC out of range
Fault
BMS
Shutdown routine 3
ETechAcknowledge
BMS-SOCO value invalid
Check the BMS information
Critical parametrization error: BMS charge current limit invalid
Fault
BMS
Shutdown routine 3
ETechAcknowledge
BMS discharge current limit invalid
Check the BMS information
Critical parametrization error: BMS discharge current limit invalid
Fault
BMS
Shutdown routine 3
ETechAcknowledge
BMS charge current limit invalid
Check the BMS information
Spare
-
Diagnostic system
7.3 Faults