5-6-3. Method of Starting and Finishing
(1) Starting the E-Mount Lens Adjustment
*
Make sure to disconnect the AC adaptor after finishing the adjustment
(including the case when stops due to an error).
*
SeusEX will start when the E-Mount Lens Adjustment is started.
Procedure of Starting
1. Set the Shooting Mode of the camera to the P mode (Program
Auto), then turn the power on.
2. Start the E-Mount Lens Adjustment.
3. The camera selection window opens, and select "ILCE-5000".
Note: Only ILCE-5000 cameras are available for the adjustment
of the unit.
4. Click the [Connect] button and check that the connection status
becomes "Connect".
[].[].[].[]
(2) Finishing the E-Mount Lens Adjustment
Procedure of Finishing
1. Click the [Disconnect] button and check that the connection
status becomes "Disconnect".
[].[].[].[]
2. Click the [] button on the upper right of the main window to
finish the E-Mount Lens Adjustment.
3. Turn off the power of camera.
4. Disconnect the AC adaptor.
5-6-4. Adjustment Method of Each Item
(1) Lens Device (S)
• Check the switch operation.
• Adjust the ring of focus, iris and zoom.
• Adjust the POWER ZOOM lever.
Subject
Operation on Lens side
Shooting Mode of the camera P mode (Program Auto)
Adjusting Method
1. Click the [Lens Device (S)] button in the Adjustment and Inspec-
tion.
2. The START screen is displayed, after the preparation of adjust-
ment is completed, press the ENTER key.
3. The message screen is displayed in the following order. Operate
the focusing ring accordance with the message.
Focusing ring
FULL MF
AF/MF
5-24
SELP18110G
Not required
• Focusing ring
• Steady shot switch
• ZOOM switch
• Zoom rotation direction
select locking switch
• Zoom ring
• Iris ring
• IRIS LOCK switch
• Iris click switch
• POWER ZOOM lever