Preparations of Using a B-L Control Box
Equipment and Tools
• Personal Computer (See Note 1)
• B-L Control Box (Supplied with D-sub 15-pin cable)
• AC cable (Sold on the market)
• RS-232C Cable (D-sub 9-pin (Male with securing screws), D-sub 9-pin (Female with securing screws)) Straight type (Sold on the market)
• USB to serial cable (D-sub 9-pin (Male)) (Sold on the market)
• Lens adjustment program (BLG-TestProgramV[][][].exe) (See Note 2)
• Lens Test Projector (F)
• E-mount APSC jig for Lens Test Projector (F) and E-mount attachment (See Note 3)
• Screen
• Tape measure
• Plane mirror (For SLRs)
Note 1: Personal computer must have the condition that Windows
Vista/7 runs normally and USB is connectable.
Note 2: For adjustment of the SELP18110G, prepare a version 1.0.0.1
or higher of the BLG-TestProgram.
Note 3: Attach the E-mount APSC jig for Lens Test Projector (F) and
the E-mount attachment suitable for the type of lens to be
tested (FF/APSC) to the Lens Test Projector.
(1) Setting of Lens Test Projector
Setting Procedure
1. Connect the B-L Control Box with the personal computer and the Lens Test Projector.
2. Attach the lens to be tested to the Lens Test Projector, and set the equipment as shown in the figure below.
3. Turn ON the main switch of the Lens Test Projector.
4. Turn ON the lamp switch of the Lens Test Projector.
5. To set the lens surface and the screen in parallel, align the plane mirror with the center projected image on the screen and adjust the lens
projector position so that the reflected light illuminates the lens to be tested.
Lens Test Projector
Main switch
6. Install the BLG-TestProgram in the following procedure.
(1) Download the file "BLG-TestProgramV[][][].zip", save and extract it.
(2) Save "BLG-TestProgramV[][][].exe" in an arbitrary folder.
Projection distance
E-mount APSC jig
Lens to be tested
E-mount attachment
B-L Control Box
D-sub 9-pin: Male
AC Cable
Lamp switch
RS-232C Cable
Screen
Plane mirror
D-sub 15-pin
cable
Personal computer
USB to Serial Cable
D-sub 9-pin: Female
5-13
SELP18110G

Advertisement

loading

This manual is also suitable for:

Alpha e pz 18-110mm f4 g ossSelp18110g