4. Examine the hydraulic oil level in the sight glass for
the hydraulic oil tank. The hydraulic oil level must not
be more than 1 cm/0.39 in. below the maximum
level.
5. If the hydraulic oil level is to low, fill with hydraulic oil.
To fill the hydraulic oil (DXR 275, DXR 305,
Refer to
DXR 315) on page 72 .
To drain the hydraulic oil (DXR 145)
WARNING:
hydraulic oil becomes hot during operation
of the product. Let the product become cool
before you drain the hydraulic oil.
1. Park the product on level ground.
2. Turn the arm system 90° to one side of the product.
3. Fully retract the arm system.
4. Fully retract the outriggers. Refer to
outriggers on page 61 .
5. Stop the product. Refer to
145) on page 62 .
1401 - 002 - 15.10.2021
MAX
MIN
Risk of burn injury. The
To operate the
To stop the product (DXR
6. Remove the 4 screws and the front cover.
7. Clean the area around the air filter.
8. Remove the air filter to release the pressure in the
hydraulic oil tank.
9. Put a container below the drain plug for the hydraulic
oil.