Resetting The Device To Factory Default - Bosch ADS-AMC2-4R4CF Installation Manual

Access modular controller 2
Hide thumbs Also See for ADS-AMC2-4R4CF:
Table of Contents

Advertisement

Access Modular Controller 2
7.2

Resetting the device to factory default

1.
2.
3.
4.
5.
6.
Figure 7.2: DIP switches and delivery status
The controller now has the following network configuration:
Bosch Security Systems B.V.
If connected to the Ethernet, release the connection.
Open the upper case of the controller as described in Opening the case, page 15 .
Reset the controller as described in Resetting the software, page 40 .
Set all six DIP switches of the RS-485 selector to ON (see figure below).
Press the reset button.
After completing this procedure, do not forget to set the DIP switches to your preferred
position (factory default 1 and 5 to ON).
DHCP = 1
IP = [assigned by DHCP server or "0.0.0.0" if not available]
Subnet mask = [assigned by DHCP server or "0.0.0.0" if not available]
Password = no password
Create your password in the IP Config settings of the AMC.
Installation manual
Troubleshooting | en
41
2022-03 | V03 |