System Overview - Bosch ADS-AMC2-4R4CF Installation Manual

Access modular controller 2
Hide thumbs Also See for ADS-AMC2-4R4CF:
Table of Contents

Advertisement

Access Modular Controller 2
3.3

System overview

The controller can be connected to the host system through one of the following interfaces,
depending on the type of installation:
The host interface is selected during installation.
The four reader interfaces are available on the device.
With RS485 operation, a maximum of eight access controllers can be connected to one party
line.
3
3
In the communication chain of a system, the access controller is integrated between the host
system and the peripheral devices.
It is possible to connect a maximum of eight readers to the access modular controller.
The four reader interfaces are divided into two physical buses. Interface 1 and 2 are on one
bus, and interfaces 3 and 4 are on the other bus. This gives the advantage in cabling: longer
cable lengths can be used (1200 m maximum per bus). Internally the buses are processed as
one interface. With this arrangement, you can connect all readers to one interface.
Bosch Security Systems B.V.
Ethernet
RS-485 multi-dropped, not supported by:
BIS 4.9.1 and later
AMS 4.0 and later.
1
2
2
4
1
Host computer
2
Access Modular Controller
3
Card reader
4
Communication and power supply
2
2
3
4
3
Installation manual