ABB ACS5000 User Manual page 58

Medium voltage ac drive air-cooled, 2 - 7 mva
Hide thumbs Also See for ACS5000:
Table of Contents

Advertisement

Chapter 3 - Control system
Modbus
Profibus
Communication with
AMC circuit board
3-12 (14)
Terminal assignment
X2:1
D(P)
Data positive
X2:2
D(N)
Data negative
X2:3
DG
Data ground
X2:4
SHF
Shield AC ground via RC filter
X2:5
SH
Shield ground direct
X2:6
0 V
Power supply (24 V (DC) +/- 10 %)
X2:7
+24 V
X2:8
PE
Ground
NPBA-12 terminal assignment
X1:1
A
Data negative (conductor 2 in twisted pair)
X1:2
B
Data positive (conductor 1in twisted pair)
X1:3
A
Data negative (conductor 2 in twisted pair)
X1:4
B
Data positive (conductor 1in twisted pair)
X2:5
24 V
Power supply (24 V (DC) +/- 10 %)
X2:6
0 V
X2:7
DG
Cable data ground (optional 3rd conductor)
Connected to module ground via a 1MOhm/15 nF RC network
X2:8
SH
Cable shield. Internally connected to module
The fieldbus adapter is connected to channel 0 of the AMC circuit board
of the INU via optical fibers.