7. SPECIFICATIONS

Functional Specifications

Line Port Interface

Connector:
Interface:
Modes:

Unit-to-Paddleboard Interface

Connector:
67
Presently used only for connecting to OC-3 JMUX unit CBW ports and cascading to another
ETHER-1000 unit.
68
CBW-6 mode is presently not used for ETHER-1000 connections.
69
Presently used only for connecting to OC-12 JMUX unit CBW ports and cascading to another
ETHER-1000 unit.
70
Also used when cascading to another ETHER-1000 unit.
Copyright  GE Multilin Inc. 2010-2012
40-conductor fine-pitch IDC
20 XMT signals and 20 RCV signals
Byte-wide data at Nx6.48 Mbyte/sec
(N=4, 6, 12, 24)
CBW-4: for 86419-01 OC-48, 86417-0X OC-12 and
86432-41 OC-3 JMUX units' CBW ports
Data rate (SONET mode) = 198.144 Mb/s
CBW-6: for 86419-01 OC-48 and 86417-0X OC-12
JMUX units‟ CBW ports
Data rate (SONET mode) = 297.216 Mb/s
CBW-12: for 86419-01 OC-48 and 86417-0X OC-12
JMUX units‟ CBW ports
Data rate (SONET mode) = 594.432 Mb/s
CBW-24: for 86419-01 OC-48 JMUX unit‟s CBW port
Data rate (SONET mode) = 1,188.864 Mb/s
48-pin DIN
342-86400-498PS