Maintenance and Disassembly
4) Disconnect the connector for fan motor from the electronic control
board (see fig. 54).
Fig. 54.
5) Remove the fixing screws of the fan motor (4 screws)
(see fig. 55).
6) Remove the fan motor.
Fig. 55.
NOTICE:
This section is for reference only. Actual unit appearance may vary.
32
3. Electrical parts
NOTICE:
Remove the panel plate and fan assembly (refer to 1. Panel plate and
2. Fan assembly) before disassembling electrical parts.
Outdoor Unit 2,6-2 / 3,5-2 / 5,3-2 OUE
1) Remove the connector for the compressor (see fig. 56).
AC Fan
2) Pull out the two blue wires connected with the four way valve
(fig. 56).
DC Fan
3) Pull out connectors of the condenser coil temp.
sensor(T3),outdoor ambient temp. sensor(T4) and discharge
temp. sensor(TP) (fig. 56).
4) Disconnect the electronic expansion valve wire (fig. 56).
5) Then remove the electronic control box (see fig. 56).
Fig. 56.
NOTICE:
This section is for reference only. Actual unit appearance may vary.
CLIMATE 5000 RAC SINGLE SPLIT (R32) – 6720894076 (2019/08)
T3, T4, TP
Compressor
Electronic Expansion Valve
4-Way Valve